Detectable and non-detectable tape
Detectable tape is a metallized tape for use with non-metallic lines, usually installed below grade approximately 6″ from the surface and can be located by any standard pipe locator. This tape is installed by utilities for gas, water, sewer, telecommunication, electric lines, and more. It can be tied in at valves, risers, etc. for easy reading without using stakes. It is easily locatable even if severed by prior diggings.
Detectable and non-detectable underground marking tape rolls available, all printed with black lettering.
Colors and legends designed in accordance with the APWA National Color Code.
Meets the below compliance testing:
- ASTM D2103-08: Standard Specification for Polyethylene Films and Sheeting.
- ASTM D882-09: Standard Test Method for Tensile Properties and Elongation of Thin Plastic Sheeting.
- ASTM D882-75B
- ASTM D2578-08: Standard Test Method for Wetting Tension of Polyethylene and Polypropylene Films.
- ASTM D792-08: Standard Test Methods for Density of Plastics by Displacement.
- ASTM D671-93: Standard Test Method for Flexural Fatigue of Plastics.
Legend | Color | Width | Detectable or Non-detectable |
---|---|---|---|
AMMONIA LINE BURIED BELOW | Yellow | 6″ | Non-detectable |
AWSS WATER LINE BURIED BELOW | Yellow | 6″ | Non-detectable |
BACKWASH RETURN LINE BURIED BELOW | Green | 3″ | Detectable |
BACKWASH SUPPLY LINE BURIED BELOW | Green | 3″ | Detectable |
CATHODIC PROTECTION LINE BURIED BELOW | Yellow | 3″ | Non-detectable |
CAUSTIC SODA LINE BURIED BELOW | Yellow | 3″ | Detectable |
CHEMICAL LINE BURIED BELOW | Yellow | 3″ | Detectable |
CHILLED WATER LINE BURIED BELOW | Blue | 6″ | Non-detectable |
CHLORINE LINE BURIED BELOW | Yellow | 6″ | Detectable |
CHLORINE SOLUTION LINE BURIED BELOW | Yellow | 3″ | Detectable |
CHLORINE VACUUM LINE BURIED BELOW | Yellow | 3″ | Detectable |
CONDENSATE LINE BURIED BELOW | Yellow | 6″ | Detectable |
CONDENSER WATER LINE BURIED BELOW | Blue | 6″ | Detectable |
COMMUNICATION LINE BURIED BELOW | Orange | 6″ | Detectable |
COMMUNICATION LINE BURIED BELOW | Orange | 3″ | Detectable |
COMMUNICATION LINE BURIED BELOW | White | 6″ | Detectable |
DIESEL LINE BURIED BELOW | Yellow | 6″ | Detectable |
DOMESTIC WASTEWATER LINE BURIED BELOW | Green | 6″ | Non-detectable |
DOMESTIC WELL WATER LINE BURIED BELOW | Green | 3″ | Non-detectable |
DRAIN LINE BURIED BELOW | Green | 3″ | Detectable |
ELECTRIC LINE BURIED BELOW | Yellow | 2″ | Non-detectable |
ELECTRIC LINE BURIED BELOW | Yellow | 3″ | Non-detectable |
ELECTRIC LINE BURIED BELOW | Yellow | 6″ | Non-detectable |
ELECTRIC LINE BURIED BELOW | Red | 2″ | Detectable |
ELECTRIC LINE BURIED BELOW | Red | 3″ | Detectable |
ELECTRIC LINE BURIED BELOW | Red | 6″ | Detectable |
ELECTRIC LINE BURIED BELOW | Red | 3″ | Non-detectable |
ELECTRIC LINE BURIED BELOW | Red | 6″ | Non-detectable |
ELECTRIC LINE BURIED BELOW | Orange | 6″ | Detectable |
FERRIC CHLORIDE LINE BURIED BELOW | Yellow | 3″ | Detectable |
FILTRATE LINE BURIED BELOW | Greem | “ | Detectable |
FIRE MAIN | Red | 3″ | Detectable |
FIRE MAIN | Red | 6″ | Detectable |
FIRE MAIN | Red | 3″ | Non-detectable |
FIRE MAIN | Red | 6″ | Non-detectable |
GAS LINE BURIED BELOW | Yellow | 2″ | Detectable |
GAS LINE BURIED BELOW | Yellow | 3″ | Detectable |
GAS LINE BURIED BELOW | Yellow | 6″ | Detectable |
GAS LINE BURIED BELOW | Yellow | 3″ | Non-detectable |
GAS LINE BURIED BELOW | Yellow | 6″ | Non-detectable |
HEAT RESERVOIR LINE BURIED BELOW | Yellow | 3″ | Detectable |
HEAT RESERVOIR LINE BURIED BELOW | Red | 3″ | Detectable |
HIGH PRESSURE LINE BURIED BELOW | Yellow | 6″ | Non-detectable |
HIGH VOLTAGE LINE BURIED BELOW | Orange | 6″ | Detectable |
HOT WATER LINE BURIED BELOW | Yellow | 3″ | Non-detectable |
HOT WATER LINE BURIED BELOW | Yellow | 6″ | Non-detectable |
INDUSRIAL WASTE LINE BURIED BELOW | Yellow | 6″ | Non-detectable |
IRRIGATION LINE BURIED BELOW | Blue | 6″ | Non-detectable |
IRRIGATION LINE BURIED BELOW | Green | 6″ | Non-detectable |
JP-8 LINE BURIED BELOW | Yellow | 6″ | Detectable |
KINDER MORGAN LINE BURIED BELOW | Yellow | 12″ | Non-detectable |
LIQUID PETROLEUM LINE BURIED BELOW | Yellow | 6″ | Non-detectable |
LOW PRESSURE SLUDGE GAS LINE BURIED BELOW | Yellow | 3″ | Non-detectable |
MIXED LIQUOR LINE BURIED BELOW | Green | 3″ | Detectable |
NON POTABLE WATER LINE BURIED BELOW | Green | 2″ | detectable |
OIL LINE BURIED BELOW | Red | 6″ | Detectable |
OIL LINE BURIED BELOW | Orange | 6″ | Non-detectable |
OIL LINE BURIED BELOW | Yellow | 3″ | Detectable |
OIL LINE BURIED BELOW | Yellow | 6″ | Detectable |
OXYGEN LINE BURIED BELOW | Yellow | 6″ | Detectable |
PIPELINE BURIED BELOW | Yellow | 3″ | Detectable |
PIPELINE BURIED BELOW | Yellow | 6″ | Detectable |
PIPELINE BURIED BELOW | Yellow | 6″ | Non-detectable |
PIPELINE BURIED BELOW | Green | 6″ | Non-detectable |
POLYELECTROLYTE LINE BURIED BELOW | Yellow | 3″ | Detectable |
POTABLE WATER LINE BURIED BELOW | Yellow | 3″ | Detectable |
PRIMARY EFFLUENT LINE BURIED BELOW | Green | 3″ | Detectable |
PROCESSED WATER LINE BURIED BELOW | Green | 6″ | Non-detectable |
RAW SEWAGE LINE BURIED BELOW | Green | 2″ | Detectable |
RECLAIMED WASTEWATER LINE BURIED BELOW | Green | 6″ | Non-detectable |
RECLAIMED WATER LINE BURIED BELOW | Green | 3″ | Detectable |
RECLAIMED WATER LINE BURIED BELOW | Purple | 2″ | Detectable |
RECLAIMED WATER LINE BURIED BELOW | Purple | 3″ | Detectable |
RECLAIMED WATER LINE BURIED BELOW | Purple | 6″ | Detectable |
RECLAIMED WATER LINE BURIED BELOW | Purple | 3″ | Non-detectable |
RECLAIMED WATER LINE BURIED BELOW | Purple | 6″ | Non-detectable |
RECLAIMED WATER LINE BURIED BELOW | Purple | 12″ | Non-detectable |
RECLAIMED WATER LINE BURIED BELOW | Yellow | 6″ | Detectable |
RECLAIMED WATER DO NOT DRINK | Purple | 3″ | Non-detectable |
RETURN SECONDARY SLUDGE LINE LINE BURIED BELOW | Green | 3″ | Detectable |
SANITARY DRAIN LINE BURIED BELOW | Green | 3″ | Detectable |
SANITARY SEWER LINE BURIED BELOW | Green | 2″ | Detectable |
SECONDARY SLUDGE LINE BURIED BELOW | Green | 3″ | Detectable |
SECONDARY SLUM LINE BURIED BELOW | Green | 3″ | Detectable |
SECURITY CABLE LINE BURIED BELOW | Yellow | 3″ | Non-detectable |
SEWER LINE BURIED BELOW | Green | 2″ | Detectable |
SEWER LINE BURIED BELOW | Green | 3″ | Detectable |
SEWER LINE BURIED BELOW | Green | 4″ | Detectable |
SEWER LINE BURIED BELOW | Green | 3″ | Non-detectable |
SEWER LINE BURIED BELOW | Green | 6″ | Non-detectable |
SEWER LINE BURIED BELOW | Green | 12″ | Non-detectable |
SEWER LINE BURIED BELOW | Beige | 3″ | Non-detectable |
SEWER LINE BURIED BELOW | Beige | 6″ | Non-detectable |
SLUDGE GAS SCRUBBING WATER LINE BURIED BELOW | Green | 6″ | Non-detectable |
SODIUM HYPOCHLORITE LINE BURIED BELOW | Yellow | 3″ | Detectable |
STEAM LINE BURIED BELOW | Yellow | 6″ | Detectable |
STORM DRAIN LINE BURIED BELOW | Green | 3″ | Detectable |
STORM DRAIN LINE BURIED BELOW | Green | 6″ | Detectable |
STORM DRAIN LINE BURIED BELOW | Green | 6″ | Non-detectable |
STORM SEWER LINE BURIED BELOW | Green | 3″ | Non-detectable |
STORM SEWER LINE BURIED BELOW | Green | 6″ | Non-detectable |
STORM WATER LINE BURIED BELOW | Green | 3″ | Detectable |
STORM WATER LINE BURIED BELOW | Green | 6″ | Detectable |
STORMWATER LINE BURIED BELOW | Blue | 3″ | Detectable |
STORMWATER LINE BURIED BELOW | Blue | 6″ | Detectable |
SULFUR DIOXIDE LINE BURIED BELOW | Yellow | 3″ | Detectable |
TANK DRAIN LINE BURIED BELOW | Green | 3″ | Detectable |
TELEPHONE LINE BURIED BELOW | Orange | 2″ | Detectable |
TELEPHONE LINE BURIED BELOW | Orange | 3″ | Detectable |
TELEPHONE LINE BURIED BELOW | Orange | 6″ | Detectable |
TELEPHONE LINE BURIED BELOW | Orange | 6″ | Non-detectable |
TRANSFER SLUDGE LINE BURIED BELOW | Green | 3″ | Detectable |
TREATED WASTEWATER LINE BURIED BELOW | Green | 3″ | Non-detectable |
UTILITY LINE BURIED BELOW | Green | 3″ | Detectable |
UTILITY LINE BURIED BELOW | Red | 6″ | Non-detectable |
UTILITY LINE BURIED BELOW | Green | 3″ | Detectable |
WATER LINE BURIED BELOW | Blue | 2″ | Detectable |
WATER LINE BURIED BELOW | Blue | 3″ | Detectable |
WATER LINE BURIED BELOW | Blue | 6″ | Detectable |
WATER LINE BURIED BELOW | Blue | 12″ | Detectable |
WATER LINE BURIED BELOW | Blue | 3″ | Non-detectable |
WATER LINE BURIED BELOW | Blue | 6″ | Non-detectable |
WATER LINE BURIED BELOW | Blue | 12″ | Non-detectable |
WATER LINE BURIED BELOW | Red | 6″ | Non-detectable |
WATER LINE BURIED BELOW | Green | 2″ | Detectable |
WATER LINE BURIED BELOW | Green | 6″ | Detectable |
WATER LINE BURIED BELOW | Green | 3″ | Non-detectable |
WATER LINE BURIED BELOW | Green | 6″ | Non-detectable |